Here are the equations for this section:
Try answering the questions and working the problems below to test your understanding of thermodynamics.
The following problems should be worked sequentially. They put together absorption, heat capacity, radiation and conduction to estimate how a house responds to heating from the sun.
Next we look at radiation and conduction. In the solution to previous problem, we found that the overall temperature of the roof would increase by about 8oC from the radiation absorption. But the roof will not heat up evenly. The exterior surface of the roof will begin to heat up first and that heat will be conducted to the interior. At the same time, heat will be radiating away from the roof because it will be warmer than the surrounding environment. There are a lot of things happening at once, so we will estimate the extreme values and then discuss the results of all these calculations.
| Review Thermodynamics |
Solutions
Don't look at the answers until you've tried the problems on your own!!
Solutions for the sequenced problems.
DQ / Dt = (1000 W/m2) (.08) (80) = 6.3 kW
The actual value would vary from near zero at sunrise to this max value and then back to zero at sunset. The average would be only about half this value.
Since we want the total heat absorbed for the day, we should use the average absorption, or about 3 kW = 3000 J/s. For 12 hours, that would be a total energy of
DQ = DQ / Dt x Dt = 3,000 J/s x (12 hrs x 60 min/hr x 60 s/min) = 1.3 x 108 J.
1.3 x 108 = (18,400) (900 J/kgoC) DT
solving we get DT = 7.9 oC. (That's about 14 degrees Fahrenheit.)
The maximum amount of heat radiated away, .32 kW, is very small compared to the maximum absorption of 6.3 kW. Even if we double the temperature increase of the roof to 16 oC, the heat radiated away is only .679 kW, only about 10% of the absorption rate.
DQ / Dt = (.8) (80) (8) / (.1) = 5 kW
This is nearly the same rate at which heat was being absorbed from the sun's radiation! We will see below why this is not reasonable.
The max value is probably reasonably accurate for a clear sunny day ... and the roof is not dirty, which would increase the emissitivity value and the absorption. Using half the max absorption rate to calculate the total day's absorption should be reasonable if it stayed sunny all day.
We did not account for the steel rebar in the concrete. Steel has a much lower heat capacity and would make the temperature increase greater. But rebar usually constitutes only a small percentage of the total mass and our omission is probably not serious.
The temperature icnrease also assumed that all the heat absorbed stayed in the roof. How good of an assumption was this? That can be answered by looking at how much energy was re-radiated away.
As mentioned before, this is very small compared to the absorption. We did not include the interior surface, but since the temperature there should be less, it will also radiate less than .32 kW ... unless the interior is painted a dark color. If it were dark, with an emissitivity = .8, then the interior would radiate ten times as much as the outside at the same temperature. This could be significant! It is rare to paint a ceiling dark, but a roof constructed of dark red wood or mahagony is not so rare. Heat radiation is a problem in these cases and plenty of cross ventilation is required to keep the interior of the roof as cool as possible. This type of cooling is convective. The cooler air comes in contact with the roof and carries away heat energy.
This value is nearly the same as the max absorption value, and is in fact the most erroneous estimate. Recall that we assumed an 8 oC temperature difference from outside to inside. At first, this may seem about right, but it can't be! Heat conducted at this rate would mean that essentially all the heat being absorbed was taken into the house. That would leave very little to increase the temperature of the roof. But we got the 8oC estimate by assuming essentially all the heat stayed in the roof! Consequently, the temperature difference of 8 oC was too high. We can estimate the actual temperature difference by realizing that most of the heat leaves the interior of the roof through radiation. That was only about .3 kW at maximum. Since 8 oC gave us 5 kW, a simple ratio shows that a temperature difference of about .5 oC will give us .3 kW. Note that this means the interior does indeed re-radiate at nearly the same rate as the exterior, assuming similar environmental temperatures. (We would also need to include convective cooling if cooler air was constantly blowing over the interior surface. That would increase the rate of heat conduction to the interior, but reduce the radiation since the surface temperature would be less.)
| RETURN |